Fire alarm module wiring diagram

1、 Overview
The fire alarm module is an important part of the fire alarm and linkage fire fighting system, responsible for receiving fire alarm signals, controlling fire equipment, etc. The correct wiring method is crucial for ensuring the normal operation of the fire security system.
2、 Module type and wiring requirements
1. Smoke detector module: Two signal lines need to be connected to the module box in the fire control room; At the same time, two power cords need to be connected to the power module.
2. Fire broadcast module: One audio cable needs to be connected to the broadcast equipment; At the same time, one signal line needs to be connected to the module box in the fire control room.
3. Fire alarm module: Two signal lines need to be connected to the module box in the fire control room; At the same time, two control wires need to be connected, one for controlling the alarm and the other for controlling the power switch.
3、 Wiring method
1. Distinguish the signal and power lines by color and identification, and connect them to the corresponding modules.
2. Use a clamp to secure the signal line and use screws to secure the power line.
3. Connect the fire-fighting equipment and control equipment properly, and check if the wiring is correct and secure.
After wiring is completed, check and control the resistance and voltage of the circuit to ensure compliance with requirements.
4、 Safety Tips
1. During the wiring process, it is necessary to ensure the safety of the circuit and avoid damaging it, which may cause short circuits or open circuits.
2. Pay attention to safety when connecting the power supply to prevent electric shock accidents.
When dealing with fire-fighting equipment, it is necessary to operate according to relevant regulations to ensure the safety of personnel.
4. Professional tools such as multimeters should be used when handling circuits to avoid damaging the equipment.
5、 Summary
The correct wiring method is the key to ensuring the normal operation of the fire security alarm module, while also ensuring the safety and stability of the entire fire protection system. During the wiring process, it is necessary to pay attention to safety, connect the circuit correctly according to the requirements, and ensure that the resistance and voltage of the circuit meet the requirements. At the same time, different types of fire protection modules need to be connected according to different wiring requirements to ensure the correctness and stability of the connection. Finally, it is important to keep in mind the precautions that need to be taken when dealing with fire-fighting equipment and circuits to ensure the safety of personnel and the normal operation of equipment.